KNORR-BREM
KBAE4535A KBAE4535A Multi-circuit Protection Valve M/PROT VALVE ISUZU

Technical Information:
Air Inlet port(s) size: VOSS NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,25,26: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,5-0,3 / >=5,7
Circuit 1 - Pressure Limiting [bar]: 9.3 +0.0/-0.3
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,5-0,3 / >=5,7
Circuit 2 - Pressure Limiting [bar]: 9.3 +0.0/-0.3
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,3-0,3 / >=5,5
Circuit 3 - Pressure Limiting [bar]: 8,3 +0,0/-0,3
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,3-0,3 / >=5,5
Circuit 4 - Pressure Limiting [bar]: 8,3 +0,0/-0,3
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
KNORR-BREM
KBAE4603 KBAE4603 Multi-circuit Protection Valve M/PROT VALVE

Technical Information:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,3-0,3 / >4,8
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,3-0,3 / >4,8
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
5,8-0,3 / >3,8
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
5,8-0,3 / >3,8
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 2
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
KNORR-BREM
KBAE4604 KBAE4604 Multi-circuit Protection Valve MULTI PROT VALVE VOLV

Technical Information:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24,11,12: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,3-0,3 / >4,8
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,3-0,3 / >4,8
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
5,8-0,3 / >3,8
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
5,8-0,3 / >3,8
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 2
Circuits' supply:
External series supply from 3
With Electrical pressure sensing: No
KNORR-BREM
KBAE4608 KBAE4608 Multi-circuit Protection Valve MULTI PROT VALVE

Technical Information:
Air Inlet port(s) size: Flange
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
>=7,5 / 6,5 +-0,25
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
>=7,5 / 6,5 +-0,25
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
<=8,0 / >=6,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
<=8,0 / >=6,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
KNORR-BREM
KBAE4613 KBAE4613 Multi-circuit Protection Valve 4 CIRCUIT VALVE = AE4610 + fitting

Technical Information:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
6,9-0,3 / >=4,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
6,9-0,3 / >=4,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,0-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6,9-0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
KNORR-BREM
KBAE4646 KBAE4646 Multi-circuit Protection Valve MULTI PROT VALVE Replaces VPS45A

Technical Information:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
<= 7.5 / 6,5+0,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
<= 7.5 / 6,5+0,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
Pmax 21 or 22 + (0,2-0,5)/ 6.5+1
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
Pmax 21 or 22 + (0,2-0,5)/ 6.5+1
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
KNORR-BREM
KBAE4653 KBAE4653 Multi-circuit Protection Valve M/PROT VALVE = VPS48H

Technical Information:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
6.3-0.3 / >=4,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
6.3-0.3 / >=4,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6.7+0.3 / >=4,0
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6.3-0.3 / >=4,0
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
KNORR-BREM
KBAE4654 KBAE4654 Multi-circuit Protection Valve MULTI PROT VALVE = VPS48H1

Technical Information:
Air Inlet port(s) size: 1/2"-14 NPTF
Air Delivery port(s) size: 21,22,23,24: 3/8"-18NPTF
Circuit 1: Feedback with no Bypass
Circuit 1 - Open/close pressure [bar]:
6.3 -0.3 / >=4,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with no Bypass
Circuit 2 - Open/close pressure [bar]:
6.3 -0.3 / >=4,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
6.7+0.3 / >=4,0
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
6.3 -0.3 / >=4,0
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
KNORR-BREM
KBAE4800 KBAE4800 Multi-circuit Protection Valve MULTI PROT VALVE

Technical Information:
Air Inlet port(s) size: Flange
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22X1,5; 27,28:M12x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: Yes